DIGITAL LHD CABLE

Shield Digital Linear Heat Detection Cable

uses xed temperature detection technology to provide an easy method for sensing changes in temperature levels. The cable can oer alternative overheat protection in a vast range of applications and environments, from tunnels, cable trays, warehousing to sensing changes in temperature within escalators and other applications where many risks of re are hidden from view.

 

The digital linear hear detection cable can be directly connected to a single zone of a conventional fire alarm control panel, or, using an addressable zone/switch monitor, the digital linear heat detection cable can easily be interfaced to an addressable loop.

 

Digital linear heat detection cable is comprised of a pair of twisted low resistance, tri-metallic conductors, sheathed in advanced temperature sensitive polymers. When the cable reaches the required temperature the two twisted cores will fuse together, with a re triggering resistor attached to the input interface and single core of linear heat cable to activate an alarm at the main fire panel.

 

DIGITAL CONTROL MODULE

A UL864 10th edition approved Digital Control Module is available and provides additional benefits when used with the Digital LHD cable. It can simultaneously monitor up to two zones of LHD cable and has separate fault and alarm outputs for each zone. A built in display shows the state of each zone, including the distance in meters and feet to the alarm point if an alarm is triggered. It also includes an RS-485 Modbus RTU output for integration with a PLC or SCADA system.

FEATURES

 

  • UL 521 Approved.
  • CE Marked.
  • Up to 10,000ft (3000m) per zone.
  • Detection along the entire length of sensor cable.
  • Optional Nylon extrusion offering UV protection and increased durability for outdoor use.
  • Optional Polypropylene extrusion for increased chemical protection in caustic environments.
  • Optional stainless steel over-braiding for increased mechanical protection.

 

Construction

Overall insulated, twisted pair of tri-metallic cores

Insulation

1kV tested protective outer coat

Additional Insulation Options

Nylon, Polypropylene or Stainless Steel braiding

Approvals

CE Marked, RoHS Compliant, UL

Maximum Zone Length

3,000m (10,000ft)

Wire Overall Diameter

3.60mm to 5.08mm (0.142″ to 0.200″)

Minimum bend radius

50 mm (2″)

Ambient Temperature Range: (dependent upon action temperature)

-40°C – 125°C (-40°F – 257°F)

ELECTRICAL

Max Voltage Rating

30Vac, 42Vdc

Resistance

~100/km (29/kft) per leg

Velocity of Propagation

~55%

Capacitance

88 – 150 pF/m (26 – 45 pF/ft)

Inductance

540 – 1050 nH/m (165 – 320 nH/ft)

Other Products of SHIELD



NEO SERIES-CONTROL PANEL

NEO SERIES-CONTROL PANEL

OMEGA SERIES-CONTROL PANEL

OMEGA SERIES-CONTROL PANEL

AURA SEREIS-CONTROL PANEL

AURA SEREIS-CONTROL PANEL

SMOKE DETECTOR Second

SMOKE DETECTOR Second

HEAT DETECTOR

HEAT DETECTOR

MULTI DETECTOR

MULTI DETECTOR

BEAM DETECTOR

BEAM DETECTOR

MANUAL CALL POINT

MANUAL CALL POINT

HORN WITH STROBE

HORN WITH STROBE

SOUNDER

SOUNDER

INPUT/MODULE

INPUT/MODULE

OUTPUT MODULE

OUTPUT MODULE

ISOLATOR MODULE Second

ISOLATOR MODULE Second

FIRE ALARM CABLE

FIRE ALARM CABLE

ALPHA 5000 (SHIELD)

ALPHA 5000 (SHIELD)

S-A4045 (SHIELD)

S-A4045 (SHIELD)

ALPHA 1000 (SHIELD)

ALPHA 1000 (SHIELD)

CHINESE BRAND

CHINESE BRAND

EXTINGUISHING CONTROL PANEL

EXTINGUISHING CONTROL PANEL